• OLIP MCM STEADY, Motor Current meter

    ◆ 3-phase, AC (not suitable for DC motors), fixed speed (line driven) motors.
    ◆ Operating Temperature : 0 – 40⁰ C (32 – 104⁰ F)

    ◆ High Voltage Models (>480 Vac) : Three Cat II Voltage Transformers*: 0.5% accuracy; 100 V, 110 V, or 120 V secondary voltages

Features

MCM provides both mechanical (unbalance, misalignment, roller bearings, etc.) and electrical (loose windings, short circuits, etc.) anomaly detection as well as electrical parameters such as voltage and current imbalances and power factor. In addition, it can detect changes in the load the motor is experiencing due to anomalies in the driven equipment or process such as cavitations or plugged filters and screens. Since it doesn’t require any sensor installation on the motor itself or associated load, MCM is especially attractive for inaccessible driven equipment and is applicable to most types of pumps, compressors, and similar loads.

Description

Motor Condition Monitor for Steady Speed Motors

MCM continuously identifies existing and developing faults on electric motors and their driven equipment. MCM utilizes an intelligent, model-based approach to provide anomaly detection by measuring the current and voltage signals from the electrical supply to the motor. It is permanently mounted, generally in the motor control center and is applicable to 3-phase AC, induction or synchronous, fixed speed motors. Accompanying MCMScada Software or OLIP Enterprise Server (OPC Server) is used to view the data.

Technical Specifications

General Information
Motor Type 3-phase, AC (not suitable for DC motors), fixed speed (line driven) motors.

Motor current (load) variation must be less than 15% during 6 sec data acquisition period. Not for use with soft-starter systems unless they are automatically bypassed immediately after motor start-up and during subsequent use

Environmental
Operating Temperature 0 – 40⁰ C (32 – 104⁰ F)
Humidity Up to 90% RH, non-condensing
INPUTS
Power Input Required 100-240 Vac, 47 – 64 Hz, 19 VA, 200 mA or 120-300 Vdc, 19 VA, 200 mA (use UL listed fuse with proper voltage rating)
MEASUREMENT VOLTAGE INPUTS
Low Voltage Models (≤480 Vac) Can tap directly off voltage lines to motor
High Voltage Models (>480 Vac) Three Cat II Voltage Transformers*: 0.5% accuracy; 100 V, 110 V, or 120 V secondary voltages
MEASUREMENT CURRENT INPUTS Three 250 Vac, Cat II Current Transformers*: 0.5% accuracy, with either 5A or 1A secondary outputs depending on MCM model
OUTPUTS
Communications RS422/RS485 (RS232 and Ethernet with additional appropriate converter)
Relay One assignable relay output, user programmable; NC/NO contacts (2A, 30VDC)
PHYSICAL
Weight 1170 g (2.58 lb)
Dimensions WxHxL 96 mm x 96 mm x 140 mm (3.78 in x 3.78 in x 5.51 in)
Protection Class Front Panel: IP 40, Whole Unit: IP 20
Mounting Front Panel Mounting (indoor)
COMPLIANCE & CERTIFICATIONS
EMC EMC Directive 2004/108/EC, EN 61326-1, IEC 61326-1

Measurement Control and Laboratory Use for Industrial Environments

Safety Electrical Safety Directive 2006/95/EC, EN 61010-1, UL 61010-1, IEC 61010-1

Safety Requirements for Electrical Equipment