- 2-meter drop resistance
- 1.3 million pixels ccd image
- Various temperature Measurement functions
- IP54
- JPEG Storage with Voice Annotation
- High cost-effective
- 160*120 pixels
Description
– A wide temperature measurement range makes the P500 suitable for many proactive maintenance programs and high temperature applications.
– High thermal sensitivity enables applications, such as air ingress and building moisture, to be easily visualized where small temperature variations matter.
– Visual and audible temperature limit alarm function alerts the user to abnormal conditions.
– Automatic hot and cold spot cursors quickly pinpoints the extremes in a scene.
– Isotherms, temperature gradients and area analysis boxes for advanced scene analysis.
– Built-in emissivity tables allow for easy emissivity value setting.
– Images can be voice annotated for later reviewing with the PC software.
Video output function allows the live image to be shown on an external display, useful when showing to a group of people.
Technical Specification
Item | P200 | P500 | |
Detector characteristics | Detector type | Uncooled FPA microbolometer | |
Array size/format | 160×120 | 384×288 | |
Image manage | Field of view/min focus distance | 25o×19o /0.1m | |
Spatial resolutions(IFOV) | 2.72mrad | 1.36mrad | |
Thermal sensitivity | ≤0.06℃@30℃ | ≤0.05℃@30℃ | |
Frame rate | 50/60Hz | ||
Focus | Manual | ||
Spectral range | 8~14um | ||
Built-in visible light | Yes | ||
Image display | LCD display | 2.7″TFT color LCD,640×480 | |
Image adjustment | Auto/manual gain and brightness | ||
Color palette | Color palette 11 palettes changeable | ||
Measurement | Temperature ranges | -20℃~+350℃ (can expand to 650℃) | -20℃~+650℃ |
Accuracy | ±2℃ or ±2% of reading, whichever is greater | ||
Measurement correction | Automatic/manual | ||
Measurement mode | Up to 4 movable spots. Up to 3 movable areas(maximum, minimum and average temperatures).Up to 3 movable lines.Line profile. Isotherms. Temperature difference. Alarm(voice,color) | ||
Setup functions | Date/time, temperature unit, language | ||
Emissivity correction | Variable from 0.01 to 1.0 | ||
Backgroud temperature correction | Automatic correction according to user input | ||
Atmospheric transmission correction | Automatic correction according to user input object distance, humidity and temperature |
||
Image storage | Storage Card | 2G SD card, max 16G | |
Storage mode | Automatic/manual single file saving, IR and Visual image link saving | ||
Thermal file format | JPEG with original thermal measurement data | ||
Visual file format | JPEG | ||
Voice annotation | A built-in microphone Up to 60 seconds of digital voice clip with each cared thermal imaging | ||
Laser pointer | Laser pointer | Class 2,1mw/635nm(red),IEC 60 285 | |
Power supply | Battery type | Li-Ion, rechargeable | |
Battery operating time | 3 hours continuous operation | ||
Charging system | Intelligent charger or power supply adaptor 12V (optional) to random charge | ||
Power saving | Auto dormancy and auto-shut down | ||
Environment | operating temperature | -15 ℃ – +50 ℃ | |
Storage temperature | -25 ℃ – +60 ℃ | ||
Encapsulation | IP54 | ||
Anti-shock | 25G , IEC 68-2-29 | ||
Vibration resistance | 2G , IEC 68-2-6 grade | ||
Drop resistance | 2 meters | ||
Humidity | ≤ 90% non-condensing | ||
Physical characteristics | Weight | 0.98kg | |
Dimensious | 230mm×105mm×245mm | ||
Handrail | Can be installed on both sides | ||
Tripod | 1/4″-20-UNC | ||
Interface | Memory card slot | Micro SD(TF) | |
External DC input | Yes | ||
Video output | Yes | ||
USB | Mini-USB Image,measurement data transfer |