Technical Specifications
Size | 8.7” x 3.7” x 1.8” (220 mm x 95mm x 45mm) |
Weight | 1.1 lb (500g)(not including accelerometer) |
Environmental | Water: MIL-STD-810F, Method 512.4 IP67 sealed against accidental immersing (1m for 30 min)Drop: MIL-STD-810F, Method 516.5, Procedure IV 26 drops from 1.22 m 6 additional drops at -4°F (-20°C) 6 additional drops at 140°F (60°C)Operating: -22° to 149°F (-30° to 65°C)Storage: -40° to 158°F (-40° to 70°C)Humidity: MIL-STD-810F, Method 507.4Sand and Dust: IP67, Mil-STD-810F, Method 510.4, Procedures I and II |
Power supply | Rechargeable battery (charger included) |
Battery life | Typically 20 hours operating time depending on backlight usage. |
Frequency ranges | 2 Hz to 1 kHz 2 Hz to 15 kHz |
Frequency Resolution | Up to 0.02 Hz 400, 800, 1600, 3200, 6400,12800, 25,600 or 51,200 lines FFT |
Displayed Amplitude Units | Acceleration in g Velocity in mm/s ( or inches/s) Bearing noise in BDU (bearing damage units) Displacement in Microns/Mils |
Displayed Frequency Units | Hertz (Hz), RPM or CPM |
Dynamic range | 120 dB +/- 50g to +/- 50g with standard accelerometer |
Auto set up of VA diagnostic bands (RPM = run speed) |
Instability, unbalance, misalignment & diagnostic bands looseness |
Envelope demodulation filters | Fully user selectable high pass and low pass filter cut off frequencies |
IEPE accelerometer interface | Constant current accelerometer power supply (+20 volts @ 2mA) can be switched off for use w/ BNC output control panels Supplied with BNC connection lead |
Numeric Keypad or Touch screen operation |
Stylus free collection of vibration data using numeric key pad or by touching screen |
Included accessories | • Tachometer, accelerometer (two) and cables, tachometer mount adapter • Carrying case with shoulder strap |